harmonic distortion Improvement and power factor increasing by modifying the hybrid filter structure by using fuzzy multi-objective meta-heuristic algorithms

Document Type : Original Article

Authors

Department of Electrical Engineering, University of Zabol, Zabol, Iran

10.22034/jfsa.2024.394284.1174

Abstract

Harmonics in power systems produce unsuitable effects such as saturation of iron cores of transformers and electrical machines, improper operation of protection relays and increase in losses, so they should be reduced. Moreover , a low power factor leads to occupying the capacity of lines with reactive power, which leads to additional costs in the system. This issue causes the regional power companies to consider penalties for subscribers who have a low power factor. Reducing THD and increasing power factor are two important goals in improving power quality. A capacitor can be used to compensate the power factor, as there is a possibility of resonance occurring in this situation. In order to achieve the mentioned targets, a hybrid power filter is proposed, which consists of a passive filter and an active filter. The active filter includes three parts: identification, modulation and inverter. To reduce the power rating of the active filter inverter, a passive filter is used with it. The elements of the passive filter should be determined in such a way that both the THD and power factor is optimized, so this work should be done with a multi-objective meta-heuristic algorithm, which SPEA-II algorithm is used in this manuscript. At the end, the efficiency of the proposed hybrid filter will be illustrated by simulation in MATLAB software.

Keywords

Main Subjects


[1] Hoseinpour, A. (2010). Three phase active filter with four switching inverter and variable index modulation. In 2010 First Power Quality Conferance.
 
[2] Hoseinpour, A., & Ghazi, R. (2012). Harmonic reduction in wind turbine generators using a shunt active filter. International Review on Modelling & Simulations, 5(4) 722–730.
 
[3] Marei, M. I., El-Saadany, E. F., & Salama, M. M. A. (2002). A new contribution into performance of active power filter utilizing SVM based HCC technique. In IEEE Power Engineering Society Summer Meeting, 2, pp. 1022–1026.
 
[4] Hosseinpour, A., & Sadeq, M. O. (2022). Harmonic reduction of current by using phase shifting and shunt-active filter trained by fuzzy particle swarm optimization. International Journal of Fuzzy Systems, 24(6), 2729–2739.
 
[5] HossienPour, A., & Ghazi, R. (2020). Using of a three-phase four-switch inverter equipped with a variable index PWM to improve the power quality of a wind power plant. International Journal of Industrial Electronics Control and Optimization, 3(3), 213–222.
 
[6] Sasaki, H., & Machida, T. (1971). A new method to eliminate AC harmonic currents by magnetic flux compensation-considerations on basic design. IEEE Transactions on Power Apparatus and Systems, 90(5), 2009–2019.
 
[7] Hoseinpour, A., & Ghazi, R. (2010). Three phase active filter manufacturing correction with economy consideration for sinusoidal and none sinusoidal sources. In 2010 First Power Quality Conferance, pp. 1–6.
 
[8] Hoseinpour, A. R., & Ghazi, R. (2011). Application of VIPWM technique on three phase shunt active filters. In 2011 2nd Power Electronics, Drive Systems and Technologies Conference.
 
[9] Chen, L., Xie, Y., & Zhang, Z. (2008). Comparison of hybrid active power filter topologies and principles. In 2008 International Conference on Electrical Machines and Systems, pp. 2030–2035.
 
[10] Yu, J., Li, Y., Cao, Y., & Xu, Y. (2018). An impedance-match design scheme for inductively active power filter in distribution networks. International Journal of Electrical Power & Energy Systems, 99, 638–649.
 
[11] Khan, A., Gastli, A., & Ben-Brahim, L. (2018). Modeling and control for new LLCL filter based grid-tied PV inverters with active power decoupling and active resonance damping capabilities. Electric power systems research, 155, 307–319.
 
[12] Li, D., Yang, K., Zhu, Z. Q., & Qin, Y. (2016). A novel series power quality controller with reduced passive power filter. IEEE Transactions on Industrial Electronics, 64(1), 773–784.
 
[13] Akbari, E., & Seyyedi, A. Z. G. (2023). Power quality enhancement of distribution grid using a photovoltaic based hybrid active power filter with three level converter. Energy Reports, 9, 5432–5448.
 
[14] Venkedesh, R., AnandhaKumar, R., & Renukadevi, G. (2022). THD reduction in measurement of H-Bridge multilevel inverter using pulse modulated switching integrated with linear quadratic Regulator. Measurement: Sensors, 24, 100435.
 
[15] Jian, W., Na, H., & Dianguo, X. (2008). A 10KV shunt hybrid active filter for a power distribution system. In 2008 Twenty-Third Annual IEEE Applied Power Electronics Conference and Exposition, pp. 927–932.
 
[16] Zitzler, E., Laumanns, M., & Thiele, L. (2001). SPEA2: Improving the strength Pareto evolutionary algorithm. TIK report, 103.
 
[17] Cheng, H., Huang, W., Zhou, Q., & Cai, J. (2013). Solving fuzzy multi-objective linear programming problems using deviation degree measures and weighted max–min method. Applied Mathematical Modelling, 37(10-11), 6855–6869.
 
[18] Chen, C. H., Hong, T. P., & Tseng, V. S. (2012). Finding pareto-front membership functions in fuzzy data mining. International Journal of Computational Intelligence Systems, 5(2), 343–354.